4 System description
4.3 Network topologies
38
Lenze · Controller-based Automation - Visualisation · System Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Functions
Direct access to field devices via CANopen.
Access to the control system and the field devices connected
( 28)
Control system access via CAN if the control systems have an SDO object directory.
Control system access via Ethernet if an OPC server is available.
SDO and PDO access (only with direct drivers).
Visualisation variables can be imported from EDS/DCF/GDC files.
Runtime software available for the corresponding device series
For more information regarding the use of CANopen®, please see the following sets of
documentation:
"Controller-based Automation" system manual
"Controller-based Automation - CANopen®" communication manual
Hardware HMI Industrial PCs Controller
Embedded
Line
Command
Station
Control
cabinet PC
Cabinet Controller Panel Controller
Device series EL 100
EL 100 PLC
EL 1800 -
9800
CS 5800 -
9800
CPC 2800 3231 C 3241 C p300 p500
Example illustration
"Visu" runtime software
»VisiWinNET®«
Compact CE

1) 1) 
»VisiWinNET®«
Compact XP
- -
1) --
»VisiWinNET®«
Standard XP
- -
1) --
»VisiWinNET®«
Standard
Client/server XP
- -
1) --
Communication
CAN interface
(on board)
----- 2) -
MC-CAN2
(optional)
- -
: Function available
-: Function not available
1) For 3231 C/3241 C, only with external monitor panel/display at DVI interface.
2) Controllers p300 only support the CAN master functionality
.
Zobrazit stránku 37