Mechanical installation
Standard devices in the power range 0.25 ... 0.75 kW
EDK82ZJ003 DE/EN/FR 1.0
8
l
H1_MechINS−M_INST_TS_Mo_BL_751
2 Mechanical installation
Standard devices in the power range 0.25 ... 0.75 kW
Dimensions
8200vec027
1 Frame
2 Screw M4x10
3 Seal
4 Hexagon nut M4
5 Rear panel of the control cabinet
Dimensions [mm]
8200 vector a b b
2
c
1
c
2
d
1
d
2
d
3
e
1)
f
1)
g
E82DV251K2C
79.4
124 120
4.2 71 5
52
10 140 100 4.5
E82DV371K2C
E82DV551KxC
184 180 82
E82DV751KxC
1)
If the function module is attached: observe mounting clearance and cable bending radius. The
terminals of function modules in PT design protrude above the housing by 14 mm.
Cutout in the control cabinet
Dimensions [mm]
8200 vector a
1
b
1
Frame
E82DV251K2C
61
101 E82ZJ007V
E82DV371K2C
E82DV551KxC
161 E82ZJ003
E82DV751KxC