3.10 L_CanDSxCloseNodeGuarding − Deactivation of "Node Guarding"
Function library LenzeCanDSxDrv.lib
Functions/function blocks
3−14
L
LenzeCanDSxDrv.lib EN 1.2
3.10 L_CanDSxCloseNodeGuarding − Deactivation of "Node
Guarding"
Function
This function is used to deactivate the "Node Guarding" monitoring mechanism of the CanDSx driver.
· For deactivation, the transfer parameter bClose must be set to TRUE.
Declaration
BOOL L_CanDSxCloseNodeGuarding (bClose);
Transfer parameters Data type Information/possible settings
bClose Bool Deactivation of the "Node Guarding" monitoring mechanism.
TRUE The "Node Guarding" monitoring mechanism of the CanDSx driver is deactivated.
Return value Data type Value/meaning
Bool Status
TRUE The "Node Guarding" monitoring mechanism of the CanDSx driver has been
deactivated.
FALSE The "Node Guarding" monitoring mechanism of the CanDSx driver has not been
deactivated.
· Remedy: Call the function with transfer parameter bClose = TRUE.
Example
Calling the function in ST:
bReturnCloseNodeGuarding := L_CanDSxCloseNodeGuarding(bClose:=
TRUE);