Drive PLC Developer Studio
Editors
7-41
l DDS EN 2.3
7.6.5 The LD in online mode
• In online mode, all contacts and coils in ON status (TRUE) are marked blue in the LD.
• In online mode, all lines in TRUE status are marked blue in the LD.
• The values of the associated variables are displayed at function block inputs and outputs.
• Breakpoints can only be set to networks. In single-stepping mode, the process jumps to
every single network one after the other.
• On active flow control, the number fields of the processed networks will be marked green.
Tip!
Positioning the mouse pointer briefly over a variable will display a tool tip with the variable’saddress,
type and any comments.