Troubleshooting and fault elimination7
EN
14
Lenze ¯ MA 12.0015 ¯ 1.0
RemedyPossible causeFault
Irregular running
Insufficient shielding of
motor or resolver cable
Checking shielding and earth connection
Drive controller gain too
large
Adjust the gains of the controllers (see Drive
controller operating instructions)
Vibrations
Insufficiently balanced
coupling elements or
machine
Rebalance
Inadequate alignment of
drive train
Realign machine unit, check foundation if
necessary
Loose fixing screws Check and tighten screw connections
Running noises
Foreign particles inside the
motor
Repair by manufacturer if necessary
Bearing damage