Lenze Tmd Series Drives Modbus Communications Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Lenze Tmd Series Drives Modbus Communications. Lenze Tmd Series Drives Modbus Communications User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Series Drives

Tmd Series Drives Modbus Communications Reference Guide

Strany 2 - About These Instructions

RG-TDMOD 6Drive Setup & Operation2.4 Universal RegistersLenze-AC Tech manufactures several drive families. Currently the QC, MC, MCH, SC, TC, smd

Strany 3 - Contents

7 RG-TDMODDrive Setup & Operation3 Data Representation - Internal and External3.1 Register FormatAll registers are 16 bits. The data within th

Strany 4

RG-TDMOD 8Drive Setup & Operation4 Tmd Drive Setup & Operation4.1 Control ParameterIn order to communicate using Modbus protocol, the Tmd Con

Strany 5 - Safety Information

9 RG-TDMODDrive Setup & Operation4.4 Watchdog TimerThe Tmd drive is equipped with a Serial Link “Watchdog Timer”. If the Modbus Master wishes t

Strany 6

RG-TDMOD 10Drive Control & Communication4.5 Unlocking & Locking ControlsRegisters #48 and #1 are used in Unlocking and Locking Controls.• A

Strany 7 - Introduction

11 RG-TDMODDrive Control & Communication4.8 Normal Control Operation Sequence1. Power up drive.2. Set parameter C01 (Control Source Setpoint)

Strany 8

RG-TDMOD 12Drive Control & Communication5 Tmd Drive Control RegistersTable 6 describes the Tmd Drive Control Registers in ascending order of Tmd R

Strany 9 - Data & Register Format

13 RG-TDMODDrive Control & Communication5.1 AbbreviationsTable 7 lists the abbreviations used in Table 6 Tmd Drive Control Registers:Table 7: Abb

Strany 10 - Drive Setup & Operation

RG-TDMOD 14Drive Control & CommunicationNOTE 1 - Drive Control• During each write to Register #1 only one bit should be set in the drive control

Strany 11

15 RG-TDMODDrive Control & Communication5.4 Drive Hardware Configuration - Register #22Table 10 lists the Tmd Drive Hardware Configuration, Regist

Strany 12

This documentation applies to the use of an Tmd Series Variable Frequency Drive in a Modbus Network and should be used in conjunction with the Tmd Ser

Strany 13

RG-TDMOD 16Drive Control & CommunicationNOTE 4b - Actual Speed (Register #24 Bytes D2H and D2L or Register #25)• In tenths of a Hz• Most signific

Strany 14 - Monitoring Only Operation

17 RG-TDMODDrive Control & Communication5.5.4 Control Mode - Registers #24 & 27Table 14 lists the Control Mode (Register #24 byte D4L or Reg

Strany 15

RG-TDMOD 18Drive Control & Communication5.5.7 Present Fault - Registers #24 & 29Table 16 lists the Present Fault (Register #24 byte D6H of Re

Strany 16 - Drive Control Registers

19 RG-TDMODDrive Control & Communication5.7 Serial Speed - Register #40This register enables the user to set the serial speed to desired value.•

Strany 17 - 5.1 Abbreviations

RG-TDMOD 20Drive Control & Communication6 Tmd Programming Parameters6.1 FormatNOTE - AttentionParameter list presented in Section 6.2 is valid onl

Strany 18

21 RG-TDMODDrive Control & Communication6.2 Parameter ListParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of Adjust

Strany 19

RG-TDMOD 22Drive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (de

Strany 20

23 RG-TDMODDrive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (d

Strany 21

RG-TDMOD 24Drive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (de

Strany 22

25 RG-TDMODDrive Control & CommunicationParameter No. 1Tmd Register #(hexadecimalrepresentation)Parameter Name Range of AdjustmentModbus value (d

Strany 23 - 5.10 Register Version

i RG-TDMODContents1 Safety Information ...

Strany 24 - Programming Parameters

RG-TDMOD 26Drive Control & CommunicationNOTE 5 - Tmd Fault HistoryParameters c61 (Present Fault), c62 (Last Fault), c63 (Last but one Fault) and c

Strany 25 - 6.2 Parameter List

27 RG-TDMODDrive Control & Communication7 Quick Start InstructionsFollow these Quick Start instructions to use ModBus Communications for basic n

Strany 26 - RG-TDMOD 22

RG-TDMOD 28Drive Control & Communication7.2 Drive Control1. Please be advised that while the drive is under network control the local STOP circu

Strany 27 - 23 RG-TDMOD

29 RG-TDMODDrive Control & Communication7.4 Basic Drive StatusAC Tech register 24 is a 6 word entity containing the drive’s status information.

Strany 28 - RG-TDMOD 24

AC Technology Corporation630 Douglas Street • Uxbridge MA 01569 • USASales: 800-217-9100 •Service: 508-278-9100www.lenze-actech.comRG-TDMOD-e3

Strany 29 - 25 RG-TDMOD

RG-TDMOD iiContents5 Tmd Drive Control Registers ...125.1 A

Strany 30

1 RG-TDMODSafety Information1 Safety Information1.1 Warnings, Cautions and Notes1.1.1 GeneralSome parts of Lenze controllers (frequency inverters,

Strany 31 - 7 Quick Start Instructions

RG-TDMOD 2Safety Information1.1.4 Electrical ConnectionWhen working on live drive controllers, applicable national regulations for the prevention of

Strany 32 - 7.3 Basic Drive Commands

3 RG-TDMODIntroduction2 IntroductionThis document defines the specifics required for Modbus serial communication with a Lenze-AC Tech standard Tmd Ser

Strany 33 - 7.4 Basic Drive Status

RG-TDMOD 4Introduction2.2.3 Network TerminationFor an RS-485 network it is essential to install the specified termination resistors (120W), i.e. one a

Strany 34 - AC Technology Corporation

5 RG-TDMODData & Register FormatD. The function codes supported by the Tmd drives are:03 Read Holding Register (4X references). In general we

Komentáře k této Příručce

Žádné komentáře