9400 Technology applications | Actuator – speed
Parameter setting & configuration
Speed setpoint conditioning
18 L EDS94TA10010xxxx EN 1.1 - 10/2008
4.3 Speed setpoint conditioning
[4-2] Speed setpoint conditioning (schematic diagram)
The speed setpoint is defined in the Lenze setting via the analog input 1 and take place in
both directions (bipolar) and accordingly the driven machine part moves forward or
backward.
r Parameter setting: Tab Application parameters dialog level Overview
Gain Invert setpointSelection
LS_Speed...
M
Speed
setpoint
DI2DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameter Lenze setting
Value Unit
C03002 Setpoint gain 100.00 %
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
AIN 1 Speed setpoint C03000