Lenze E94AxHE Technology Application Synchronism Uživatelský manuál Strana 28

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 27
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Machine parameters
28 L EDS94TA10040xxxx EN 1.1 - 10/2008
Example of determining the machine parameters for the slave axis
O Tip!
The feed constant corresponds to the movement on the machine side when the
gearbox output shaft carries out one revolution (for selection as angle = 360°).
When the unit is set, the real unit of the machine for the selection of physical
values (e. g. speeds, accelerations and decelerations) is defined.
1. Set gearbox ratio for the motor in the form of a quotient
(numerator and denominator): i
2
= 12.612 = 12612/
1000
Numerator (C02520) = 12612
Denominator (C02521) = 1000
2. Set the same gearbox ratio for the position encoder:
Numerator (C02522) = 12612
Denominator (C02523) = 1000
3. Set feed constant (C02524).
For the conveyor drive: Vk = d
2
* π = 628,3185 mm
4. Set the selection "mm" as unit (C02525).
d
2
i
2
= 200 mm
= 12.612
Zobrazit stránku 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 79 80

Komentáře k této Příručce

Žádné komentáře