Lenze E94AYFLF Digital frequency module Uživatelský manuál Strana 36

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 54
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 35
Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C13042
36 L EDS94AYFLF EN 3.2 - 10/2010
C13042
C13050
C13051
C13052
Parameter | Name:
C13042 | Resp. to Vcc error DFIN
Data type: UNSIGNED_8
Index: 11533
d
= 2D0D
h
Digital frequency extension module in module receptacle MXI1:
Response when monitoring for encoder voltage supply at digital frequency input X9 is triggered
Monitoring is triggered if the encoder voltage controlled by the digital frequency input reaches the voltage limit.
Selection list
(Lenze setting in bold)
1Fault
2Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13050 | Signal source DFOUT
Data type: UNSIGNED_8
Index: 11525
d
= 2D05
h
Digital frequency extension module in module receptacle MXI1:
Selection of the signal source for digital frequency output X10
Selection list
(Lenze setting in bold)
1None
2 Digital frequency input DFIN
3 Motor feedback system
4 Load feedback system
5Resolver
6Encoder
7Application [Incr./ms]
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13051 | No. of increments DFOUT
Data type: UNSIGNED_32
Index: 11524
d
= 2D04
h
Digital frequency extension module in module receptacle MXI1:
Number of increments for digital frequency output X10
Definition of the number of pulses for one "mechanical" revolution.
Setting range
(min. value | unit | max. value) Lenze setting
1 16384 2048
; Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C13052 | Zero pulse offset DFOUT
Data type: UNSIGNED_16
Index: 11523
d
= 2D03
h
Digital frequency extension module in module receptacle MXI1:
Zero pulse offset for digital frequency output X10
Offset for displacing the zero pulse to be output.
Setting range
(min. value | unit | max. value) Lenze setting
0 Incr. 65535 0increments
; Read access ; Write access ; CINH PLC-STOP No transfer