56
EDKCSCE040 DE/EN/FR 3.0
Scope of supply
Position Description Number
Power supply module ECSCExxx 1
Accessory kit with attachment material 1
Mounting instructions 1
Drilling jig 1
Note!
The ECSZE000X0B connector set must be ordered separately.
Connections and interfaces
Position Description Detailed
information
X22 Connections
l External brake resistor
l DC−bus voltage
l PE
88
LEDs: Status and fault display
X1 Automation interface (AIF) for
l Communication module
l Operating module (XT keypad)
100
X2 PE connection AIF
X3 Not assigned
X4 CAN connection
l System bus (CAN)
l Interface for
– master control and other modules
– PC/HMI for parameterisation and diagnostics
101
X6 Connections
l Low−voltage supply
l Digital inputs and outputs
l Thermostat contacts
99
S1 DIP switch
l CAN node address (device address in the CAN network)
l CAN baud rate
X21 Mains connection 85
Status displays
LED
Description
Red Green
Off On Power supply module is enabled, no fault
Off Blinking Power supply module is inhibited (CINH), switch−on inhibit
Blinking, 1 Hz Off Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active
Blinking, 3 Hz Off Message active
Blinking, 1 Hz Blinking Warning active with inhibited module
Blinking, 1 Hz On Warning active with enabled module