Function library LenzeDrive.lib
Special functions
2.7.4 Speed preconditioning (L_NSET)
2−75
L
LenzeDrive.lib EN 1.7
2.7.4.2 JOG setpoints
JOG setpoints are fixed values that are stored under anJogSetValue[0] ... anJogSetValue[14] in the
memory.
The JOG values can be called up from the memory by bJog1_b ... bJog8_b.
These inputs are binary coded, so that 15 JOG values can be called.
The decoding for the enabling of the JOG values (calling from the memory) is carried out
according to the following table:
Main setpoint of bJog8_b bJog4_b bJog2_b bJog1_b
nNSet_a 0 0 0 0
anJogSetValue[0] 0 0 0 1
anJogSetValue[1] 0 0 1 0
anJogSetValue[2] 0 0 1 1
anJogSetValue[3] 0 1 0 0
anJogSetValue[4] 0 1 0 1
anJogSetValue[5] 0 1 1 0
anJogSetValue[6] 0 1 1 1
anJogSetValue[7] 1 0 0 0
anJogSetValue[8] 1 0 0 1
anJogSetValue[9] 1 0 1 0
anJogSetValue[10] 1 0 1 1
anJogSetValue[11] 1 1 0 0
anJogSetValue[12] 1 1 0 1
anJogSetValue[13] 1 1 1 0
anJogSetValue[14] 1 1 1 1
0 = FALSE
1 = TRUE
The number of VAR_INPUT variables to be assigned depends on the number of JOG setpoints
required. A maximum of 4 VAR_INPUT variables and thus 15 selection possibilities are
available.
Number of the required JOG setpoints Number of VAR_INPUT (bJog1_b ... bJog8_b) to be assigned
1 at least 1
1 ... 3 at least 2
4 ... 7 at least 3
8 ... 15 4
2.7.4.3 Setpoint inversion
The output signal of the JOG function is led via an inverter.
The sign of the setpoint is inverted, when bNSetInv_b switches = TRUE .