6.5 Selecting the counter modes EPM−T410
Function library LenzeIOSystem.lib
Appendix
6−10
L
LenzeIOSystem.lib EN 1.7
6.5 Selecting the counter modes EPM−T410
Mode
Function IN1 IN2 IN3 IN4 IN5 IN6 OUT0 OUT1 Auto
Reload
Compare
Load
[hex] [dec]
2 counters 0 1
00
h
0 32 bit counter RES CLK DIR RES CLK DIR · ·
01
h
1 Encoder 1 edge RES A B RES A B · ·
03
h
3 Encoder 2 edges RES A B RES A B · ·
05
h
5 Encoder 4 edges RES A B RES A B · ·
4 counters 0.1 0.2 1.1 1.2
08
h
8 2 × 16 bit counters
(counting direction upwards/upwards)
CLK CLK CLK CLK
09
h
9 2 × 16 bit counters
(counting direction downwards/upwards)
CLK CLK CLK CLK
0A
h
10 2 × 16 bit counters
(counting direction downwards/upwards)
CLK CLK CLK CLK
0B
h
11 2 × 16 bit counters
(counting direction downwards/upwards)
CLK CLK CLK CLK
2 counters 0 1
0C
h
12 2 × 32 bit counters (counting direction
upwards)
RES CLK GATE RES CLK GATE · · ü
0D
h
13 2 × 32 bit counters (counting direction
downwards)
RES CLK GATE RES CLK GATE · · ü
0E
h
14 2 × 32 bit counters (counting direction
upwards)
RES CLK GATE RES CLK GATE · · ü ü
0F
h
15 2 × 32 bit counters (counting direction
downwards)
RES CLK GATE RES CLK GATE · · ü ü
1 counter 0/1
10
h
16 Frequency measuring RES CLK START STOP · · ü
11
h
17 Measuring the period RES CLK START STOP · · ü
12
h
18 Frequency measuring
(output counter runs/stops)
RES CLK START STOP · · ü
13
h
19 Measuring the period
(output counter runs/stops)
RES CLK START STOP · · ü
2 counters 0 1
06
h
6 Measuring the pulse width
(f
ref
50 kHz, counting direction selectable)
RES PULSE DIR RES PULSE DIR
14
h
20 Measuring the pulse width
(f
ref
programmable, counting direction
selectable)
RES PULSE DIR RES PULSE DIR
15
h
21 Measuring the pulse width
(f
ref
programmable, counting direction
upwards)
RES PULSE DIR RES PULSE GATE
16
h
22 Measuring the pulse width
(f
ref
programmable, counting direction
downwards)
RES PULSE DIR RES PULSE GATE
2 counters 0 1
17
h
23 2 × 32 bit counters
(counting direction upwards, set function)
RES CLK GATE RES CLK GATE ü
18
h
24 2 × 32 bit counters
(counting direction upwards, set function)
RES CLK GATE RES CLK GATE ü
19
h
25 2 × 32 bit counters
(counting direction upwards, reset function)
RES CLK GATE RES CLK GATE ü
1A
h
26 2 × 32 bit counters
(counting direction upwards, reset function)
RES CLK GATE RES CLK GATE ü
2 counters 0 1
1B
h
27 32 bit counter G/RESû CLK DIR G/RESû CLK DIR · ·
1C
h
28 Encoder 1 edge G/RESû A B G/RESû A B · ·