1.3 EN - 07/2012 L 293
PLC Designer V2.x| Lenze Application Samples
The L_SCB_CANBasic.lib library
L_SCB_PutNodeDataTxPDO2 - data transmission
17.12 L_SCB_PutNodeDataTxPDO2 - data transmission
This FB transmits the data via PDO 2.
Inputs
Outputs
Note!
To be able to use the L_SCB_GetNodeDataRxPDO1/
L_SCB_GetNodeDataRxPDO2 FBs in a program, the L_SCB_CanStatus FB must
also be inserted.
Otherwise, communication to the controller is not
possible!
Identifier/data type Information/possible settings
byNodeNumber
BYTE
Node number
byMasterNumber
BYTE
Interface number (0...3)
awSendData
ARRAY[0..3] OF WORD
Data
Identifier/data type Information/possible settings
xError
BOOL
"Error" status signal
Error when reading the data of PDO2
FALSE No error detected
TRUE Error when reading the data