Commissioning
Adjusting the rotor position
6
6.8
6.8−3
EDSVS9332P EN 5.0−07/2013
Procedure
8. Inhibit controller (X5/28 = LOW).
9.
Reset C0006 to default setting if necessary.
10. Click C0003 and save the setting by selecting C0003 = 1.
11. Disconnect the mains and reconnect the motor to the machine.
Danger!
Uncontrolled movements of the drive after an "Sd7" error in
conjunction with absolute value encoders or in the case of a
"PL−TRIP" error.
If the rotor position adjustment was completed with an "Sd7" or
"PL−TRIP" error ( 9.3−1) it was not possible to assign the rotor
position to the feedback system. In this case the drive may carry
out uncontrolled movements after the controller has been
enabled.
Possible consequences:
ƒ Death or severe injuries.
ƒ Destruction or damage to the machine.
Protective measures:
ƒ Repeat rotor position adjustment (start with step 1).
ƒ Check the wiring and the interference immunity of the
encoder at X8.