Lenze · Engineer · 2.13 EN - 10/2014 195
Defining the system functionality
Creating an interconnection via the electrical shaft
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Additional process encoders and characteristics also feature individual measuring systems:
[8-15] Example: Controller interconnection with cam function and four different measuring systems
Master measuring system
Measuring system, slave 1
Measuring system, slave 3
Process encoder measuring system
Encoder for the master value selection (real master)
Drive axis 1 (slave 1)
Drive axis 2 (slave 2)
Process encoder
Note!
It is important to use the correct measuring system for the interconnection of devices.
The measuring systems do not represent the encoder but the tool or material. This
means that rotating tools are usually represented n a modulo system, for example,
whereas continuous material is represented in an unlimited measuring system.