Establishing an online connection
Going online
88
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
•Select Gateway -> EtherCAT ADS as bus connection.
3. In the area enter the access data suitable for the control.
Enter the user name, password as well as IP address and AMS-NetID of the EtherCAT
interface of the control.
4. In area , enter the EtherCAT address of the field device to which an online connection is
to be established.
Alternatively, you can press Search/enter which calls the Select Device Access Path dialog
window. As a consequence, the »Engineer« prompts the control to display the devices
detected at the EtherCAT segment.