Lenze E94AxHE Technology Application CiA402 Device profi Uživatelský manuál Strana 105

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 232
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 104
EDS94TA11010xxxx EN 1.2 - 03/2010 L 105
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
CiA402 Homing method 21
Processes:
Case 1: Axis has not yet activated reference switch:
1. Movement in negative direction with profile data set 1.
2. Reversing with positive edge of the reference switch and change to profile data set 2.
3. The following negative edge of reference switch sets reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 2: Axis already stands on reference switch:
1. Movement in positive direction with profile data set 2.
2. The following negative edge of reference switch sets reference (0x607C
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Homing switch
1
2
0
Zobrazit stránku 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 231 232

Komentáře k této Příručce

Žádné komentáře