EDS94TA11010xxxx EN 1.2 - 03/2010 L 183
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Parameterisable function blocks
3.21.3 CountMultiError
3.21.4 CountSingleError
3.21.5 DetectErrorLimit
is ans instance of Function
L_TbCount Counter for recognised telegram failures (multiple errors)
Parameter Possible settings Information
C04006 Reset function
0 After reaching the reference value
the counter is automatically reset to
the starting value.
1 The reference value reached is
stored until it is reset via
bLoadStartValue.
Lenze setting
is ans instance of Function
L_TbCount Counter for recognised telegram failures (single errors)
Parameter Possible settings Information
C04005 Reset function
0 After reaching the reference value
the counter is automatically reset to
the starting value.
1 The reference value reached is
stored until it is reset via
bLoadStartValue.
Lenze setting
is ans instance of Function
L_TbCompare Error triggering after exceeding the maximum value of the telegram failure
Comparison of the number of recognised telegram failures with the maximum
value set in C03010
.
Parameter Possible settings Information
C04085 Comparison operation
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2 Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|