Lenze E94AxHE Technology Application CiA402 Device profi Uživatelský manuál Strana 109

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 232
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 108
EDS94TA11010xxxx EN 1.2 - 03/2010 L 109
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
CiA02 homing method 25
Processes:
Case 1: Axis does not activate reference switch on the way to the limit switch:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. The following positive edge of reference switch sets reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 2: Axis activates reference switch first on the way to the limit switch:
1. Movement in positive direction with profile data set 1.
2. The following positive edge of reference switch sets reference (0x607C
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 3: Axis already stands on reference switch:
1. Movement in positive direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Homing switch
Positive travel range limit switch
1
3
2
0