EDS94TA11010xxxx EN 1.2 - 03/2010 L 53
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
3.7.2.7 Reset fault
This command serves to acknowledge an existing error message if the cause of the error
has been eliminated.
The pulse inhibit remains set.
It is changed to the device state "Switch on disabled
", i.e. the switch on inhibit is active.
[3-8] Possible state changes through "Reset fault" command
Bit pattern for "Reset fault" command in 0x6040 (control word):
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reset fault Operating mode-dependent control bits Enable
operation
Quick stop Enable voltage Switch on
0 Ê 1 X X XXXXX
From all states
Power section inhibited (pulse inhibit)
Power section enabled
1
2
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
active
Switch on
disabled
Quick stop
active
Power on