Interface PLC <˘> NC operating system
Extended interface for MMI functions
Data blocks 8 ... 14
5
5.2
5.2.1
l
270
EDSTCXN EN 2.0
5.2 Extended interface for MMI functions
5.2.1 Data blocks 8 ... 14
DB8 data word Name Direction
DW000 − 255 reserved
DB9 data word Name Direction
DW000 − 255 reserved
DB10 data word Name Direction
DW000 − 255 reserved
DB11 data word Name Direction
DW000 − 247 reserved
DW250 − 253 Target position block axis 0 PLC ← NC
DW254 − 255 Target position block axis 1 (LOW−WORD) PLC ← NC
DB12 data word Name Direction
DW000 − 255 reserved
DW000 − 001 Target position block axis 1 (HIGH−WORD) PLC ← NC
SW002 − 005 Target position block axis 2 PLC ← NC
DW006 − 009 Target position block axis 3 PLC ← NC
DW010 − 013 Target position block axis 4 PLC ← NC
DW014 − 017 Target position block axis 5 PLC ← NC
DW018 − 021 Target position block axis 6 PLC ← NC
DW022 − 025 Target position block axis 7 PLC ← NC
DW026 − 029 Target position block axis 8 PLC ← NC
DW030 − 033 Target position block axis 9 PLC ← NC
DW034 − 037 Target position block axis 10 PLC ← NC
DW038 − 041 Target position block axis 11 PLC ← NC
DW042 − 045 Distance between current zero point and home position
axis 0
PLC ← NC
DW046 − 049 Distance between current zero point and home position
axis 1
PLC ← NC
DW050 − 053 Distance between current zero point and home position
axis 2
PLC ← NC
DW054 − 057 Distance between current zero point and home position
axis 3
PLC ← NC
DW058 − 061 Distance between current zero point and home position
axis 4
PLC ← NC
DW062 − 065 Distance between current zero point and home position
axis 5
PLC ← NC
DW066 − 069 Distance between current zero point and home position
axis 6
PLC ← NC
DW070 − 072 Distance between current zero point and home position
axis 7
PLC ← NC
DW074 − 077 Distance between current zero point and home position
axis 8
PLC ← NC
DW078 − 081 Distance between current zero point and home position
axis 9
PLC ← NC
DW082 − 085 Distance between current zero point and home position
axis 10
PLC ← NC
Assignment