L-force | PLC Designer
Lenze Specific Functions
DMS 4.1 EN 03/2011 TD29 39
Outputs (VAR_OUT)
Designator / Data type Value / Meaning
xDone This output is set to TRUE when the parameter has been written
correctly.
xBusy This output is set to TRUE as long as the writing has not been completed.
xError This output is set to TRUE if an error occurs during writing. eError
outputs the cause of the error.
ErrorID Error number
xValueStored_PosEdge Measured value saved after triggering on positive edge
lrRecordedPosition_PosEdge Measured value in the case of triggering with the positive edge in
SoftMotion units [SM units], i.e. the measured value is supplied to the
PLC application in the same unit in which the axis is programmed.
xValueStored_NewEdge Measured value saved after triggering on negative edge.
lrRecordedPosition_NegEdge Measured value in the case of triggering with the negative edge in
SoftMotion units [SM units], i.e. the measured value is supplied to the
PLC application in the same unit in which the axis is programmed.
xActivationLevel Level of the TP input at the time of TP function activation in the drive.
The application can detect the nature of the first active edge by
evaluating the activation level when a "positive or negative edge" is
assigned.
xCommandAborted Block aborted by means of L_SMCAbortTrigger. The outputs "Busy" and
"Done" are reset.