Lenze PLC Designer R3-x Uživatelský manuál Strana 136

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 159
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 135
The L_LCB_LogicControlBasic library
L_LCB_Speed_sToSpeed_v - signal converter
136
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.17 L_LCB_Speed_sToSpeed_v - signal converter
This FB converts a 3 bit speed signal into a 16 bit speed signal.
Input
Output
13.18 L_LCB_Speed_vToSpeed_s - signal converter
This FB converts a 16 bit speed signal into a 32 bit speed signal.
Input
Output
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_Speed_sToSpeed_v
DINT diIn_s iOut_v INT
Identifier/data type Information/possible settings
diIn_s
DINT
Input signal in [rpm] 15000 rpm 2
26
= 67108864
Identifier/data type Value/meaning
iOut_v
INT
Output signal in [rpm]
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_Speed_vToSpeed_s
BOOL iIn_v diOut_s DINT
Identifier/data type Information/possible settings
iIn_v
INT
Input signal in [rpm] 15000 rpm 2
14
= 16384
Identifier/data type Value/meaning
diOut_s
DINT
Output signal in [rpm] 15000 rpm 2
26
= 67108864
Zobrazit stránku 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 158 159

Komentáře k této Příručce

Žádné komentáře