12 Diagnostics
12.6 System error messages
186
Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x9811005C ETC_E_SDO_ABORTCODE_DICTIONARY The dynamic object directory generation has failed, or no object directory is
available
Abort code 0x08000023
0x9811005D ETC_E_SDO_ABORTCODE_UNKNOWN Unknown internal slave error
0x98110060 ETC_E_FOE_ERRCODE_NOTDEFINED Manufacturer-specific FoE error
0x98110061 ETC_E_FOE_ERRCODE_NOTFOUND Not found
0x98110062 ETC_E_FOE_ERRCODE_ACCESS Access denied
0x98110063 ETC_E_FOE_ERRCODE_DISKFULL Memory (floppy disk/hard disk) is full.
0x98110064 ETC_E_FOE_ERRCODE_ILLEGAL Invalid/impermissible
0x98110065 ETC_E_FOE_ERRCODE_PACKENO Wrong package number
0x98110066 ETC_E_FOE_ERRCODE_EXISTS Already available
0x98110067 ETC_E_FOE_ERRCODE_NOUSER User/consumer is missing.
0x98110068 ETC_E_FOE_ERRCODE_BOOTSTRAPONLY Only bootstrap state
0x98110069 ETC_E_FOE_ERRCODE_NOTINBOOTSTRAP No bootstrap state
0x9811006A ETC_E_FOE_ERRCODE_INVALIDPASSWORD No required access authorisation
0x9811006B ETC_E_FOE_ERRCODE_PROGERROR Program error
0x98110070 ETC_E_CFGFILENOTFOUND The master configuration has not been found.
0x98110071 ETC_E_EEPROMREADERROR Command error during EEPROM upload
0x98110072 ETC_E_EEPROMWRITEERROR Command error during EEPROM download
0x98110073 ETC_E_XML_CYCCMDS_SIZEMISMATCH The cyclical command has a wrong size or is too long.
Internal error. Please contact Lenze.
0x98110074 ETC_E_XML_INVALID_INP_OFF Invalid input offset in cyclical command
Internal error. Please contact Lenze.
0x98110075 ETC_E_XML_INVALID_OUT_OFF Invalid output offset in cyclical command
Internal error. Please contact Lenze.
0x98110076 ETC_E_PORTCLOSE Closing of the port failed.
Internal error. Please contact Lenze.
0x98110077 ETC_E_PORTOPEN Opening of the port failed.
Internal error. Please contact Lenze.
0x98110078 ETC_E_SOE_ERRORCODE_INVALID_ACCESS Impermissible access to element 0
Is not supported.
0x98110079 ETC_E_SOE_ERRORCODE_NOT_EXIST Nonexistent
Is not supported.
0x9811007a ETC_E_SOE_ERRORCODE_INVL_ACC_ELEM1 Impermissible access to element 1
Is not supported.
0x9811007b ETC_E_SOE_ERRORCODE_NAME_NOT_EXIST The name is not available.
Is not supported.
0x9811007c ETC_E_SOE_ERRORCODE_NAME_UNDERSIZE The name is too short for transmission.
Is not supported.
0x9811007d ETC_E_SOE_ERRORCODE_NAME_OVERSIZE The name is too short for transmission.
Is not supported.
0x9811007e ETC_E_SOE_ERRORCODE_NAME_UNCHANGE The name cannot be changed.
Is not supported.
0x9811007f ETC_E_SOE_ERRORCODE_NAME_WR_PROT The name is currently write-protected.
Is not supported.
0x98110080 ETC_E_SOE_ERRORCODE_UNDERS_TRANS The attribute is too small for transmission.
Is not supported.
0x98110081 ETC_E_SOE_ERRORCODE_OVERS_TRANS The attribute is too big for transmission.
Is not supported.
0x98110082 ETC_E_SOE_ERRORCODE_ATTR_UNCHANGE The attribute cannot be changed.
Is not supported.
0x98110083 ETC_E_SOE_ERRORCODE_ATTR_WR_PROT The attribute is currently write-protected.
Is not supported.
0x98110084 ETC_E_SOE_ERRORCODE_UNIT_NOT_EXIST The unit is not available.
Is not supported.
0x98110085 ETC_E_SOE_ERRORCODE_UNIT_UNDERSIZE The unit is too small for transmission.
Is not supported.
0x98110086 ETC_E_SOE_ERRORCODE_UNIT_OVERSIZE The unit is too big for transmission.
Is not supported.
Error no.
[hex]
Designation Description