3.5 System error messages
9300 Servo PLC
Appendix
3−108
L
9300 Servo PLC EN 5.1
System error message Possible settings/response
Lenze setting setting possible
Available in
No. Display Source Meaning
Code TRIP Message Warning FAIL−QS
P
Off Drive
PLC
Servo
PLC
ECSxA
x089 PL MCTRL Error during rotor position adjustment
x091 EEr FWM External monitoring activated via DCTRL C0581
x105 H05 internal Internal error (memory)
x107 H07 internal Internal error (power stage)
x108 H08 internal Extension board not connected correctly or not
supported by program
x110 H10 FWM Temperature sensor error: heatsink
temperature
C0588
x111 H11 FWM Temperature sensor error: temperature inside
the controller
FIF−CAN / CAN−AUX communication error:
x122 CE11
FIF−CAN1 FIF−CAN1_IN (monitoring time can be set under
C2457/1)
C0591
CANaux1 CANaux1_IN (monitoring time can be set under
C2457/1)
C2481
x123 CE12
FIF−CAN2 FIF−CAN2_IN (monitoring time can be set under
C2457/2)
C0592
CANaux2 CANaux2_IN (monitoring time can be set under
C2457/2)
C2482
x124 CE13
FIF−CAN3 FIF−CAN3_IN (monitoring time can be set under
C2457/3)
C0593
CANaux3 CANaux3_IN (monitoring time can be set under
C2457/3)
C2483
x125 CE14
FIF−CAN FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C0595
FIF−CAN FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C2484
x126 CE15 FIF−CAN Communication error of the gateway function
(C0370, C0371) via FIF−CAN
C2485
x190 nErr MCTRL Speed out of tolerance margin (C0576) C0579
x200 NMAX MCTRL Maximum speed exceeded (C0596)
Time−out (see task configuration):
x201 overrun Task1
internal
Task with ID 2
2)
x202 overrun Task2 Task with ID 3
x203 overrun Task3 Task with ID 4
x204 overrun Task4 Task with ID 5
x205 overrun Task5 Task with ID 6
x206 overrun Task6 Task with ID 7
x207 overrun Task7 Task with ID 8
x208 overrun Task8 Task with ID 9
x219 overrun Cycl.−T internal Time−out in cyclic task (PLC_PRG, ID 1)
2)
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP
2)
In DDS adjustable under Project W Exception response