9300 Servo PLC
System blocks
2.4 AIF_IO_Management (node number 161)
2−25
L
9300 Servo PLC EN 5.1
2.4.2 Outputs_AIF_Management
This SB transfers commands and messages to a fieldbus module connected to an automation
interface (AIF).
For this purpose C2120 provides a control word. The commands are specified as numbers. Some
command numbers are universally applicable for all fieldbus modules, others apply only for special
modules. The total number of commands available can amount to up to 16.
Tip!
Read the documentation for the attached fieldbus module.
Bit 7
Toggle-Bit (MSB)
Bit 8 … 15
AIF control word
Outputs_AIF_Management
AIF_wControl
C2120
Bit0…6
Fig. 2−8 System block "Outputs_AIF_Management"
System variables
Variable Data type Signal type Address Display code Display
format
Note
AIF_wControl Word %QX161.0 C2120
Codes
Code LCD
Possible settings
Info
Lenze Selection
C2120 AIF: Control
AIF command
0 No command
1 Read CAN codes + reinitialisation
2 Read XCAN codes
10 Read XCAN C2356/1 ... 4
11 Read XCAN C2357
12 Read XCAN C2375
13 Read XCAN C2376 ... C2378
14 Read XCAN C2382
255 Not assigned