3.6 Code table
9300 Servo PLC
Appendix
3−142
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0603 MONIT CE5 3 System bus: Monitoring configuration
Time−out when remote parameterisation is activated
(C0370)
0 TRIP
2 Warning
3 Off
C0606 MONIT OC8 2 Configuration of the I
2
× t−advance warning
The threshold is set in C0127.
0 TRIP
2 Warning
3 Off
C0608 ovr Tx−Queue 0 System bus: Monitoring configuration
Free CAN objects: Tx buffer (transmission memory
overflow)
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP
C0609 over Rx−lsr 0 System bus: Monitoring configuration
Free CAN objects: Too many telegrams received
0 TRIP
4 FAIL−QSP
C0855 DIS: IN (0−15)
g
Automation interface (AIF): Process data input words
0000 {hex} FFFF
Hexadecimal value is bit−coded:
1 Bit 00 AIF1_bInB0_b
Bit 01 AIF1_bInB1_b
...
Bit 15 AIF1_bInB15_b
AIF1_IN: Process data input word 3
2 Bit 00 AIF1_bInB16_b
Bit 01 AIF1_bInB17_b
...
Bit 15 AIF1_bInB31_b
AIF1_IN: Process data input word 4
C0856 DIS: IN.Wx
g
Automation interface (AIF): Process data input words
−32768 {1 %} 32767
1 AIF1_IN: Process data input word 2 (AIF1_nInW1_a)
2 AIF1_IN: Process data input word 3 (AIF1_nInW2_a)
3 AIF1_IN: Process data input word 4 (AIF1_nInW3_a)
C0857 DIS: IN.D1
g
Automation interface (AIF): Process data input word
AIF1_dnInD1_p (32−bit angle information)
−2147483648 {1} 2147483647
C0858 DIS: OUT.Wx
g
Automation interface (AIF): Process data output words
−32768 {1 %} 32767
1 AIF1_OUT: Process data output word 2 (AIF1_nOutW1_a)
2 AIF1_OUT: Process data output word 3 (AIF1_nOutW2_a)
3 AIF1_OUT: Process data output word 4 (AIF1_nOutW3_a)
C0859 DIS: OUT.D1
g
Automation interface (AIF): Process data output word
AIF1_dnOutD1_p (32−bit phase information)
−2147483648 {1} 2147483647