9300 Servo PLC
System blocks
2.9 DFOUT_IO_DigitalFrequency (node number 22)
2−43
L
9300 Servo PLC EN 5.1
2.9 DFOUT_IO_DigitalFrequency (node number 22)
2.9.1 Inputs_DFOUT / Outputs_DFOUT
This SB converts internal speed signals into frequency signals and outputs them to X10.
The transmission is very precise with the remainder being considered (no offset and gain
errors).
DFOUT_IO_DigitalFrequency
X10
C0540
0
1
2
4
5
0
1
2
4
5
CTRL
C0545
C0540
C1799
C0030
C0547
n
ma x
C0540
X8
X9
DFOUT_nOut_v DFOUT_nIn_v
X7
C0549
Fig. 2−19 Digital frequency output (DF_OUT)
System variables
Variable Data type Signal type Address Display
Code
Display
Format
Note
DFOUT_nOut_v Integer Velocity %QW22.0 C0547
C0549
dec [%]
dec [rpm]
DFOUT_nIn_v Integer Velocity %IW22.0
Tip!
The process image is newly created for every task the SB is used in.
If DFOUT_nIn_v and DFOUT_nOut_v are used in several tasks, an own process image of the
SB is created for each of these tasks.
This process is different from the previous process image creation principle!
The signals of the digital frequency output X10 are TTL−compatible.
The output signal corresponds to the simulation of an incremental encoder:
Track A, track B and the zero track (if necessary) as well as the corresponding inverted
tracks are output with tracks shifted by 90°.