3.6 Code table
9300 Servo PLC
Appendix
3−22
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
C0030 DFOUT const 3 Constant for the digital frequency output
0 256increments per revolution
1 512increments per revolution
2 1024increments per revolution
3 2048increments per revolution
4 4096increments per revolution
5 8192increments per revolution
6 16384increments per revolution
C0032 FCODE Gearbox 1 Freely configurable code (absolute analog signals)
FCODE_nC32_a (gearbox factor numerator)
−32767 {1} 32767
C0034 Mst current 0 Analog input AIN1_nIn_a:
Selection: Master voltage/master current for setpoint
selection
0 −10 V ... + 10 V
1 +4 mA ... +20 mA
2 −20 mA ... +20 mA
C0037 Set−value rpm 0 Freely configurable code (absolute speed signals)
FCODE_nC37_a (setpoint selection in rpm)
−16000 {1 rpm} 16000
C0040 Ctrl enable 1 Controller inhibit (CINH)
Write to code: Enable/inhibit controller
Read code: Read controller status
0 Controller inhibited
1 Controller enabled
C0042 DIS: QSP
g
Quick stop status (QSP)
0 QSP not active
1 QSP active
C0043 Trip reset 0 TRIP reset
0 TRIP−RESET (Current TRIP reset)
1 Error occurred (TRIP is active)
C0050 MCTRL−NSET2
g
Speed setpoint at speed controller input (nNsetIn_a)
−100.00 {0.01 %} 100.00
C0051 MCTRL−NACT
g
Actual speed value
−30000 {1 rpm} 30000
C0052 MCTRL Umot
g
Motor voltage
0 {1 V} 800
C0053 UG−VOLTAGE
g
DC−bus voltage
0 {1 V} 900
C0054 Imot
g
Motor current
0.0 {0.1 A} 500.0
C0056 MCTRL−MSET2
g
Torque setpoint (nMSetIn_a)
−100.00 {0.01 %} 100.00
C0057 Max torque
g
Maximum possible torque of the drive configuration
Dependent on C0022, C0086
0.0 {0.1 Nm} 500.0
C0058 Rotor diff 0.0 Zero phase of the rotor for synchronous motors (C0095)
−180.0 {0.1 _} 179.9
C0059 Mot pole no.
g
Pole pair number of the motor
1 {1} 50
C0060 Rotor pos
g
Current rotor position
1 rev. = 2048 inc
0 {1} 2047