3.6 Code table
9300 Servo PLC
Appendix
3−40
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
[C0490] Feedback pos 0 Feedback system for the position controller
C0490 = 0, 1, 2 can be mixed with
C0495 = 0, 1, 2.
C0490 = 3, 4 also sets C0495 to the same value.
0 Resolver at X7
1 Encoder TTL at X8
2 Sin/cos encoder at X8
3 Absolute value encoder ST at X8
4 Absolute value encoder MT at X8
[C0495] Feedback n Feedback system for the speed controller
C0495 = 0, 1, 2 can be mixed with
C0490 = 0, 1, 2.
C0495 = 3, 4 also sets C0490 to the same value.
0 Resolver at X7
1 Encoder TTL at X8
2 Sin/cos encoder at X8
3 Absolute value encoder ST (single turn) at X8
4 Absolute value encoder MT (multi turn) at X8
C0496 NactFilter on 0 Activation: Actual speed value filter time constant PT1
(C0497)
0 Not active
1 Active
C0497 Nact filter 2.0 Actual speed value filter time constant PT1. Has both an
effect on the system variable MCTRL_nNAct_a and on the
following speed control.
0.0 {0.1 ms} 50.0
0 ms = switched off
C0504
PLC memory: RAM access via codes
More detailed information can be found in chapter
3.6.2, "RAM access via codes".
^ 3−52
C0505
C0506
C0507
C0508
C0509
C0510 ProtAppFlash 0 PLC memory: Write protection of the application FLASH
0 No write protection
1 Write protection