3.6 Code table
3−37
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
C0381 HeartProTime 0 System bus: Heartbeat (slave): HeartbeatProducerTime
Time interval for sending the "heartbeat" message.
Only relevant for setting C0352 = 3.
Additional information about the "heartbeat" function
can be found in the Manual for the function library
LenzeCanDSxDrv.lib.
0 {1 ms} 65535
C0382 GuardTime 0 System bus: Node guarding (slave): NodeGuardTime
Time interval for the status request from the master.
Only relevant for setting C0352 = 4.
Additional information about the "node guarding"
function can be found in the Manual for the function
library LenzeCanDSxDrv.lib.
0 {1 ms} 65535
C0383 LifeTimeFact. 0 System bus: Node guarding (slave): NodeLifeTime factor
Factor for the NodeLifeTime monitoring time:
NodeLifeTime = C0383 x C0382 (NodeGuardTime)
Only relevant for setting C0352 = 4.
Additional information about the "node guarding"
function can be found in the Manual for the function
library LenzeCanDSxDrv.lib.
0 {1} 255
C0384 Err NodeGuard 3 System bus: Node guarding (slave):
Response to a "node guarding" event.
Only relevant for setting C0352 = 4.
Additional information about the "node guarding"
function can be found in the Manual for the function
library LenzeCanDSxDrv.lib.
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP
C0400 DIS: OUT
g
Analog input terminal 1/2 (AIN1_nIn_a)
−199.99 {0.01 %} 199.99
C0405 DIS: OUT
g
Analog input terminal 3/4 (AIN2_nIn_a)
−199.99 {0.01 %} 199.99
[C0416] Resolver adj 0 Correction of the resolver error
For Lenze motors:
Read resolver error from the nameplate
0 {1} 99999999
[C0420] Encoder const 512 Encoder: Constant for encoder input X8
1 {1 inc/rev} 8192
[C0421] Enc voltage 5.00 Encoder: Supply voltage for the encoder
CAUTION: Incorrect input may destroy the encoder
5.00 {0.1 V} 8.00
C0425 DFIN const 3 Digital frequency input DFIN_IO_DigitalFrequency:
Number of increments of the encoder input
0 256increments per revolution
1 512increments per revolution
2 1024increments per revolution
3 2048increments per revolution
4 4096increments per revolution
5 8192increments per revolution
6 16384increments per revolution
C0426 DIS: OUT
g
Digital frequency input DFIN_IO_DigitalFrequency:
DFIN_nIn_v
−32767 {1 rpm} 32767
Zobrazit stránku 138