9400 HighLine | Parameter setting & configuration
Basic drive functions
Manual jog
156 Firmware 1.37 - 09/2006 L
9.4 Manual jog
The basic function "Manual jog" serves to traverse the drive manually, e.g. to clean or
exchange the tool.
r Optionally, you can change over to a second manual speed during the process.
r A "retracting" from operated travel range limit switches is also supported. Then, you
can only traverse in the corresponding retracting direction.
9.4.1 Parameter setting
r Parameterisation dialog in the »Engineer«: Tab Application parameter dialog level
Overview All basic functions Manual jog
r Short overview of the parameters for manual jog:
Note!
In the manual mode the travel mode is monitored via limit switches and
software limit positions by the basic function "Limiter
". (C 200)
Stop!
When the reference is not known and no software limit positions are set, the
drive can run into a mechanical limit during the manual jog and machine parts
can be destroyed or damaged!
Parameters Information
C02620
Manual jog speed 1
C02621
Manual jog speed 2
C02622
Manual acceleration
C02623
Manual deceleration
C02624
Inaccuracy time of manual traversing