Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Uživatelský manuál Strana 372

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 679
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 371
9400 HighLine | Parameter setting & configuration
TAs for positioning tasks
TA "Multi-purpose positioning" | Basic signal flow
372 Firmware 1.37 - 09/2006 L
13.2.1 Basic signal flow
The functional core of the multi-purpose positioning is formed by the sequence table and
the profile data management, which transmit the required control signals and profile data
to the basic drive function "Positioning".
[13-3] Signal flow of the TA "Multi-purpose positioning" (schematic diagram)
Multi-purpose positioning
Sequence table
Profile data management
Speed/acceleration override
Basic drive functions
Homing
Positioning
Manual jog
Stop
Quick stop
Limiter
! Brake control (optional)
3
024
6
78
91
5
DI7
DI6
AIN1
PositionerTable
Profiles
Multi-purpose positioning
Override
Enable
AIN2
Speed override
Acceleration override
Sequencer
LS_ManualJog
n
t
è
ç
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
n
t
LS_Stop
internal
status machine
Status
machine
(basic drive
functions)
Basic drive functions
M
0-100 100 200
LS_Homing
n
t
LS_Positioner
DI2
DI4
DI3
DI1
DI5
Reset
Sequencer
input 8
DI8
Zobrazit stránku 371