L Firmware 1.37 - 09/2006 411
9400 HighLine | Parameter setting & configuration
TAs for positioning tasks
TA "Table positioning"
13.3 TA "Table positioning"
The technology application "table positioning" enables the drive to execute
parameterisable travel profiles. The sequence is controlled by a superimposed control (e.g.
PLC).
Functions
r Control of the program flow via predefined ports
r Positioning in different positioning modes
Point-to-point positioning
Touch probe positioning (residual path positioning)
Profile chaining with velocity changeover (overchange)
r Homing in different homing modes
r Profile data management
Support of S profiles (jerk limitation)
Separate setting for acceleration and deceleration
"Teach" function
r Speed-/acceleration override
r Following error monitoring
r Support of absolute value encoders
r Support of the basic drive functions "Manual jog" and "Quick stop"
r Monitoring of travel range limits with the basic drive function "Limiter"
r Optional control of a holding brake with the basic drive function "Brake control"
Note!
With the exception of the sequence table, the functionality of the table
positioning is identical to the multi-purpose positioning.
The different functions are described in the previous chapter on TA "Multi-
purpose positioning". (C 371)