9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
478 Firmware 1.37 - 09/2006 L
CAN on board: Invalid node address 0 [0x00830001]
CAN on board: Invalid basic configuration [0x00830002]
CAN on board: Heartbeat error index 1 [0x00840000]
CAN on board: Heartbeat error index 2 [0x00840001]
CAN on board: Heartbeat error index 3 [0x00840002]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause Remedy
CAN on board: Initialisation error
The node address has been selected via DIP switch by
means of hardware and the DIP switches of the node
address are set to zero.
Note: Instead of the impermissible node address 0 the
node address 1 is used.
Use the DIP switches to set a node address unequal 0
and restart the controller.
Activate the node number assignment by means of
software by changing the position of DIP switch 2 and
restart the controller.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause Remedy
CAN on board: Configuration error
Faulty download of an Engineer or PLC Designer
project
Invalid CAN settings according to DS301V402 in the
Engineer or PLC Designer.
Repeat download
Correct CAN settings in the project and regenerate
project.
Response (Lenze setting printed in bold) Setting: C00613/1 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CAN on board: Cyclic node monitoring
Node device has not received a heartbeat telegram
from node 1 within the defined time.
Reactivate CAN node by restarting the controller,
restart of the controller (C00002
="11000") or CAN
reset node.
Select a different heartbeat producer monitoring
time or switch off monitoring and reset locked error
status, if necessary.
Tip: Safe the current parameter set before mains
switching and restart (C00002
="11").
Response (Lenze setting printed in bold) Setting: C00613/2 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CAN on board: No heartbeat telegram received from
node 2.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C00613/3 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CAN on board: No heartbeat telegram received from
node 3.
See remedy for "Heartbeat error index 1".