5 Motor interface
5.8 Parameterisable additional functions
204
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5. Set the gain Vp in C00075
and the reset time Tn in C00076, which have been determined during
the adjustment with rated motor current (in this example "5 A"):
• Set C00075
= "10 V/A".
• Set C00076
= "5 ms".
6. Scale the Vp values on the Y axis of the characteristic to the 100 % Vp setting in C00075
:
[5-26] Scaling of the determined saturation characteristic to the "100 %" setting in C00075
7. Enter the Vp values in percent, which are placed on the interpolation point, in C02853/1...17:
[5-27] Interpolation point values of the saturation characteristic determined
15 A
234567891011121314151617
7.5 A3.75 A 11.25 A 12.38 A5A
0 6.25 12.5 18.75 25 31.25 37.5 43.75 50 56.25 62.5 68.75 75 81.25 87.5 93.75 100
Vp [%]
0A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
0
10
20
30
40
50
60
70
80
90
100
110
120
130
C00075 = "10 V/A" 100 %º
1
I
max
[%]
234567891011121314151617
0 6.25 12.5 18.75 25 31.25 37.5 43.75 50 56.25 62.5 68.75 75 81.25 87.5 93.75 100
Vp [%]
30
40
57.5
65
72.5
80
87.5
95
107
130
50
45
35
0
1
I
max
[%]
Interpolation
point
Setting Interpolation
point
Setting
1 C02853/1
= 130 % 10 C02853/10 = 72.5 %
2 C02853/2
= 130 % 11 C02853/11 = 65 %
3 C02853/3
= 130 % 12 C02853/12 = 57.5 %
4 C02853/4
= 130 % 13 C02853/13 = 50 %
5 C02853/5
= 130 % 14 C02853/14 = 45 %
6 C02853/6 = 107 % 15 C02853/15 = 40 %
7 C02853/7
= 95 % 16 C02853/16 = 35 %
8 C02853/8
= 87.5 % 17 C02853/17 = 30 %
9 C02853/9 = 80 %