Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 411
11 Basic drive functions
11.5 Manual job, encoderless
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.2.3 Deactivation
The basic function is deactivated by
setting the input "MOL_bEnable" to FALSE or
removing the checkmark (if there is one) in the »Engineer« dialog box entitled Manual control
(parameter set 1).
[11-21] Deactivation of the basic function "Manual jog, encoderless"
Stop!
Before the basic function is deactivated, the controller inhibit must be set. Otherwise,
unsteady drive behaviour can occur when a changeover is made from the basic function
"Manual jog, encoderless" to the basic function "Stop".