Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 723
14 Parameter reference
14.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
204 Activate parameter set 4 Loads parameter set 4 from the memory module.
• Only possible when the application has stopped and
the controller is inhibited.
301 Archive parameter set 1 Saves the current parameter set as parameter set 1 in the
memory module.
302 Archive parameter set 2 Saves the current parameter set as parameter set 2 in the
memory module.
303 Archive parameter set 3 Saves the current parameter set as parameter set 3 in the
memory module.
304 Archive parameter set 4 Saves the current parameter set as parameter set 4 in the
memory module.
401 Internal command 401 For Lenze service only
501 Load cam data From software version V3.0
Reloads cam data from the memory module into the
controller.
• Only possible when the application has stopped and
the controller is inhibited.
• If the cam data are provided with an access
protection, the user password has to be entered in
C02900
first.
Basic function "Cam data management
"
502 Save cam data From software version V3.0
Saves the cam data available in the main memory of the
controller in the memory module with mains failure
protection.
• If the cam data are provided with an access
protection, the user password has to be entered in
C02900
first.
Basic function "Cam data management
"
503 Calculate cam data From software version V3.0
Converts the cam data available in the main memory of
the controller into the internal format and provides them
to the application.
Basic function "Cam data management
"
504 Calculate cam data checksum From software version V3.0
Recalculates the checksum of the cam data available in
the main memory of the controller.
• Required if the cam data in the main memory of the
controller have been changed via parameters.
Basic function "Cam data management
"
730 Internal command 730 For Lenze service only
731 Internal command 731 For Lenze service only
732 Internal command 732 For Lenze service only
733 Internal command 733 For Lenze service only
800 Internal command 800 For Lenze service only
810 Internal command 810
811 Internal command 811
812 Internal command 812
1001 Internal command 1001 For Lenze service only
1020 Internal command 1020 For Lenze service only
1021 Export parameters to file For Lenze service only
1030 Format file system Formats file system of the memory module.
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_32
Index: 24573
d
= 5FFD
h
Komentáře k této Příručce