Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 849
14 Parameter reference
14.2 Parameter list | C02122
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02122
C02123
C02520
C02521
C02522
Parameter | Name:
C02122 | Runtime UserTask
Data type: UNSIGNED_32
Index: 22453
d
= 57B5
h
Runtime measurement
Display range (min. value | unit | max. value)
0 μs 3600000000
Subcodes Info
C02122/1 Curr. runtime UserTask
C02122/2 Max. runtime UserTask
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02123 | Runtime IdleTask
Data type: UNSIGNED_32
Index: 22452
d
= 57B4
h
Runtime measurement
Display range (min. value | unit | max. value)
0 μs 3600000000
Subcodes Info
C02123/1 Curr. runtime IdleTask
C02123/2 Max. runtime IdleTask
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02520 | Gearbox factor numerator: Motor
Data type: INTEGER_32
Index: 22055
d
= 5627
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
1 2147483647 1
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02521 | Gearbox factor denom.: Motor
Data type: INTEGER_32
Index: 22054
d
= 5626
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
1 2147483647 1
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02522 | Gearbox factor num.: Pos. enc.
Data type: INTEGER_32
Index: 22053
d
= 5625
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
1 2147483647 1
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Komentáře k této Příručce