5 Motor interface
5.10 Internal interfaces | "LS_MotorInterface" system block
232
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Identifier
DIS code | data type
Information/possible settings
MI_dnPosCtrlAdaptLoad_n
C02568/1 | DINT
Dynamic change of the proportional gain Vp of the position controller during
operation
For software versions lower than V5.0 the following applies:
Internal limitation to 10 ... 200 %
From software version V5.0 the following applies:
Internal limitation to 0 ... 200 %
MI_dnPosCtrlAdaptMotor_n
C02568/2 | DINT
Dynamic change of the proportional gain Vp of the phase controller during
operation
For software versions lower than V5.0 the following applies:
Internal limitation to 10 ... 200 %
From software version V5.0 the following applies:
Internal limitation to 0 ... 200 %
MI_dnSpeedCtrlAdapt_n
C02568/3 | DINT
Dynamic change of the proportional gain Vp of the speed controller during
operation
• If the input is assigned, the following applies:
V
P
= MI_dnSpeedCtrlAdapt_n [%] * C00070
• If the input is not assigned, the following applies:
V
P
= 100 % * C00070 = C00070
• Internal limitation to 10 ... 200 %
Optimising the speed controller
( 147)
MI_bResetSpeedCtrlIntegrator
C02569/2 | BOOL
Reset integral action component in the speed controller
TRUE Integral action component is reset to "0".
MI_dnTorqueHighLimit_n
C02568/4 | DINT
MI_dnTorqueLowLimit_n
C02568/5 | DINT
Upper/lower limit value for correcting variable of the speed controller and total
torque setpoint
• These two inputs serve to select an external torque limitation.
If the motor torque reaches the selected limits, the drive can no longer
follow the speed setpoint!
If the torque limitation is active, the output MI_bTorqueSetpointLimited is
set to TRUE.
•100 % C00057/2
• Only a positive torque is permissible as upper limit value.
• Only a negative torque is permissible as lower limit value.
• The motor mounting position (C02527
) defines the assignment to the
limitation inputs of the motor control.
• The internally effective torque limit values are displayed in C02559/1...2
.
MI_dnFluxSetpoint_n
C02568/7 | DINT
Setpoint for the field controller
MI_dnInertiaAdapt_n
C02568/8 | DINT
Adaptation of the moment of inertia in [%]
• If input is not assigned = 100 %
• Internal limitation to 0 ... 200 %
MI_dnBoostSet_n
C02568/9 | DINT
From V3.0
Boost voltage
•100 % 1000 V
MI_bFlyingSyncBlocked
C02569/16 | BOOL
From V3.0
Block flying restart
Flying restart function
( 209)
FALSE Flying restart function is active
TRUE Flying restart process is blocked.