Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 837
14 Parameter reference
14.2 Parameter list | C01195
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01195
C01196
C01197
C01198
Parameter | Name:
C01195 | Influence winding I²xt mon.
Data type: UNSIGNED_32
Index: 23380
d
= 5B54
h
I
2
xt motor monitoring: Influence of the winding temperature
• By setting "0 %", the time constant for the winding is not considered and the thermal model is only calculated
with the time constant set for the housing/laminated core.
I2xt motor monitoring
Setting range (min. value | unit | max. value) Lenze setting
0 % 100 0%
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01196 | S1 torque characteristic I²xt mon.
Data type: UNSIGNED_32
Index: 23379
d
= 5B53
h
By selecting a characteristic, the permissible motor current is evaluated depending on speed for calculating the
thermal motor utilisation.
I2xt motor monitoring
Setting range (min. value | unit | max. value)
0 % 600
Subcodes Lenze setting Info
C01196/1 0 % S1 torque characteristic n1/nn
C01196/2 100 % S1 torque characteristic I1/In
C01196/3 0 % S1 torque characteristic n2/nn
C01196/4 100 % S1 torque characteristic I2/In
C01196/5 100 % S1 torque characteristic n3/nn
C01196/6 100 % S1 torque characteristic I3/In
C01196/7 100 % S1 torque characteristic n4/nn
C01196/8 100 % S1 torque characteristic I4/In
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01197 | Starting value I²xt monitoring
Data type: UNSIGNED_32
Index: 23378
d
= 5B52
h
From software version V11.0
I2xt motor monitoring
Setting range (min. value | unit | max. value) Lenze setting
0 % 200 0%
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01198 | Async. motor: Stall protection
Data type: UNSIGNED_32
Index: 23377
d
= 5B51
h
Setting range (min. value | unit | max. value) Lenze setting
0 % 100 0%
Read access Write access CINH PLC STOP No transfer Scaling factor: 1