Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 277
8 I/O terminals
8.3 Analog outputs
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3 Analog outputs
The controller has two analog outputs that can be used to output internal analog signals as voltage
signals, e.g. for the control of analog indicating instruments or as a setpoint for slave drives.
8.3.1 Terminal assignment/electrical data
Note!
Initialisation behaviour:
After mains switching until the application is started, the analog outputs remain on
0V.
Exception handling:
In the case of a critical exception within the application (e. g. reset), the analog
outputs are set to 0 V.
Terminal Use Electrical data
X3/AO1 Voltage output 1 Level: -10 V ... +10 V
(max. 2 mA)
Resolution: 11 bits + sign
Scaling: ±2
30
±10 V
Conversion rate: 1 kHz
X3/AO2 Voltage output 2 Level: -10 V ... +10 V
(max. 2 mA)
Resolution: 11 bits + sign
Scaling: ±2
30
±10 V
Conversion rate: 1 kHz
X3/GA Reference potential (analog ground)
GA
AO1
AO2
X3