14 Parameter reference
14.2 Parameter list | C01215
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01215
C01217
C01218
C01220
C01221
Parameter | Name:
C01215 | Set time and date
Data type: UNSIGNED_16
Index: 23360
d
= 5B40
h
From software version V1.5
Setting of the system time of the controller displayed in C01214
.
• If the MM440 memory module with real-time clock is plugged into the controller, the real-time clock is set
simultaneously.
Set time and date.
• Before writing to a subcode for the first time, the current time information according to the internal clock is
displayed in the subcodes.
• When a value has been written into a subcode, the displays in the subcodes freeze to the last values.
• The new system time set is only accepted after a value has been written into each subcode at least once.
• After the new system time has been accepted, the display in the subcodes is updated according to the internal
clock.
Note:
If a memory module without real-time clock is plugged into the controller, the internal clock is initialised with
"01.01.1970 00:00:00" every time the mains is switched on.
Setting range (min. value | unit | max. value)
0 65535
Subcodes Lenze setting Info
C01215/1 0 Seconds
C01215/2 0 Minutes
C01215/3 0 Hours
C01215/4 1 Day
C01215/5 1 Month
C01215/6 1970 Year
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01217 | Service code
Data type: VISIBLE_STRING
Index: 23358
d
= 5B3E
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01218 | Service code
Data type: UNSIGNED_32
Index: 23357
d
= 5B3D
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01220 | MEC history: RAM address
Data type: UNSIGNED_32
Index: 23355
d
= 5B3B
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01221 | MEC history: RAM value
Data type: UNSIGNED_32
Index: 23354
d
= 5B3A
h
This code is for device-internal use only and must not be written to by the user!