Lenze 9400 Uživatelský manuál Strana 674

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 954
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 673
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
674
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
MXI2: Digital frequency module is missing or incompatible [0x008c0014]
MXI1: ICM module is missing or incompatible [0x008c0015]
MXI2: ICM module is missing or incompatible [0x008c0016]
MXI1: CAN module is missing or incompatible [0x008c0017]
MXI2: CAN module is missing or incompatible [0x008c0018]
Module ID (decimal) Error ID (decimal)
140: Application project manager 20
Response (Lenze setting printed in bold) Setting: C00615/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Digital frequency extension module in module slot MXI2
is incompatible with the application.
Use extension module supported by the application.
Module ID (decimal) Error ID (decimal)
140: Application project manager 21
Response (Lenze setting printed in bold) Setting: C00615/2 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
ICM extension module in module slot MXI1 is
incompatible with the application.
Use extension module supported by the application.
Module ID (decimal) Error ID (decimal)
140: Application project manager 22
Response (Lenze setting printed in bold) Setting: C00615/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
ICM extension module in module slot MXI2 is
incompatible with the application.
Use extension module supported by the application.
Module ID (decimal) Error ID (decimal)
140: Application project manager 23
Response (Lenze setting printed in bold) Setting: C00615/2 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CANopen communication module in module slot MXI1 is
incompatible with the application.
Use communication module supported by the
application.
Module ID (decimal) Error ID (decimal)
140: Application project manager 24
Response (Lenze setting printed in bold) Setting: C00615/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CANopen communication module in module slot MXI2 is
incompatible with the application.
Use communication module supported by the
application.
Zobrazit stránku 673
1 2 ... 669 670 671 672 673 674 675 676 677 678 679 ... 953 954

Komentáře k této Příručce

Žádné komentáře