Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 733
14 Parameter reference
14.2 Parameter list | C00004
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00004
C00005
C00006
C00007
Parameter | Name:
C00004 | Service password
Data type: UNSIGNED_32
Index: 24571
d
= 5FFB
h
Service code to unlock protected device commands (C00002).
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 0
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00005 | Application selection
Data type: INTEGER_32
Index: 24570
d
= 5FFA
h
Application selection
• Use the device command C00002
="5" to activate the selected application.
Setting range (min. value | unit | max. value) Lenze setting
-1 16 0
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00006 | Select motor control
Data type: UNSIGNED_32
Index: 24569
d
= 5FF9
h
Motor interface
Selection list (Lenze setting printed in bold) Info
1 SC: Servo control sync. motor For synchronous motors with speed sensor
Servo control
2 SC: Servo control async. motor For asynchronous motors with speed sensor
Servo control
4 SLVC: Sensorless vector control From software version V3.0
Sensorless vector control
6 VFCplus: V/f control open loop From software version V3.0
V/f control
7 VFCplus: V/f control closed loop From software version V3.0
V/f control
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00007 | Active application
Data type: INTEGER_32
Index: 24568
d
= 5FF8
h
Display range (min. value | unit | max. value)
-2147483648 2147483647
Read access Write access CINH PLC STOP No transfer Scaling factor: 1