11 Basic drive functions
11.11 Limiter
514
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.11.2.5 Permissible direction of rotation
Via C02707, or alternatively via the input LIM_dwControl (generally by the control word of the
safety module) the permissible direction of rotation for the basic functions "Manual jog
", "Homing",
and "Positioning
" can be restricted.
If the permissible direction of rotation is restricted and a travel command in the inhibited
direction of rotation is requested:
The movement of the active basic function ("Manual jog
", "Homing" or "Positioning") is
cancelled.
The response parameterised in C02716/1
(Lenze setting: "No response") is activated.
The fault message "Pos. direction of rotation was limited" or "Neg. direction of rotation was
limited" is entered in the logbook of the controller.
A corresponding status is output via the LIM_dnState output.
Note!
The restriction of the permissible direction of rotation is not actively effective for the
basic functions "Speed follower
", "Torque follower" and "Position follower"!
Only the response parameterised in C02716/1
is executed.
(Lenze setting: "No response")