14 Parameter reference
14.2 Parameter list | C00648
810
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00648
C00649
C00650
C00651
C00691
Parameter | Name:
C00648 | PolePosId min.mov. gain
Data type: UNSIGNED_32
Index: 23927
d
= 5D77
h
From software version V4.0
P component of the PI controller for the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
0.00 10.00 0.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00649 | PLI min. mov. reset time
Data type: UNSIGNED_32
Index: 23926
d
= 5D76
h
From software version V4.0
I component of the PI controller for the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
0.01 ms 6000.00 62.50 ms
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00650 | PolePosId min.mov. max.perm.mov.
Data type: INTEGER_32
Index: 23925
d
= 5D75
h
From software version V4.0
Max. movement permitted during the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
9020 °
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00651 | PLI min. motion absolute cur. amp.
Data type: UNSIGNED_32
Index: 23924
d
= 5D74
h
From software version V7.0
Adjustment of the pole position identification
Display range (min. value | unit | max. value)
0.00 A 1000.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00691 | Total speed setpoint
Data type: INTEGER_32
Index: 23884
d
= 5D4C
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100