13 Diagnostics & fault analysis
13.4 Logbook
606
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.4.4 Export logbook entries to a file
How to export the logbook entries to a file:
1. Click Export... in the Logbook dialog box.
•The Export logbook dialog box is displayed.
2. Specify the folder, file name, and file type for the file.
3. Click the Save button to export the logbook entries into the given file.
Hidden logbook entries are not exported, i.e. the filter criteria specified are accounted for
during the export.
The logbook entries are written to the file in the form of a semicolon separated list.
Example
Type;event;error number;number;power-on time meter;internal clock;module
Fault;motor:overtemperature;611778563;1;16243:36:56;01.01.1970 00:00;temperature monitoring
Fault;motor:thermal detector is defective;611778572;1;16243:36:56;01.01.1970 00:00;temperature
monitoring
Fault;resolver: open circuit;612040728;1;16243:36:55;01.01.1970 00:00;motor control