14 Parameter reference
14.2 Parameter list | C00387
782
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00387
C00388
C00390
Parameter | Name:
C00387 | CAN Node Guarding Activity
Data type: BITFIELD_32
Index: 24188
d
= 5E7C
h
"CAN on board" system bus: node guarding protocol
Display area
0x00000000 0xFFFFFFFF
Value is bit-coded:
Bit 0 Node guarding of node 1
... ...
Bit 31 Node guarding of node 32
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00388 | CAN node guarding status
Data type: UNSIGNED_8
Index: 24187
d
= 5E7B
h
"CAN on board" system bus: node guarding protocol
Selection list (read only)
0 Unknown
4 Stopped
5 Operational
127 Pre-operational
Subcodes Info
C00388/1 Status node 1 ... 32
C00388/...
C00388/32
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00390 | CAN Error Register (DS301V402)
Data type: BITFIELD_8
Index: 24185
d
= 5E79
h
Mapping of the CANopen object I-1001 (see DS301 V4.02).
"CAN on board" system bus
Display area
0x00 0xFF
Value is bit-coded: Info
Bit 0 Generic error Currently only bit 0 and bit 4 contain the corresponding
information.
Bit 1 Current error (not used)
Bit 2 Voltage error (not used)
Bit 3 Temperature error (not used)
Bit 4 Communication error
Bit 5 Dev. prof. spec. err (not used)
Bit 6 Reserved
Bit 7 Manuf. spec. error (not used)
Read access Write access CINH PLC STOP No transfer Scaling factor: 1