Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 809
14 Parameter reference
14.2 Parameter list | C00644
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00644
C00645
C00646
C00647
Parameter | Name:
C00644 | PolePosId 360° fault tol.
Data type: INTEGER_32
Index: 23931
d
= 5D7B
h
From software version V4.0
Fault tolerance for the plausibility check of the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
-6.0 ° 30.0 0.0 °
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00645 | PLI 360° absolute current amplitude
Data type: UNSIGNED_32
Index: 23930
d
= 5D7A
h
From software version V7.0
Adjustment of the pole position identification
Display range (min. value | unit | max. value)
0.00 A 1000.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00646 | PLI min.mov. curr. amplitude
Data type: UNSIGNED_32
Index: 23929
d
= 5D79
h
From software version V4.0
Percentage adjustment of the current amplitude for the pole position identification
Stop!
If there is no temperature monitoring in the motor and/or the I2xt motor monitoring is not parameterised correctly,
the motor may be permanently damaged when the current amplitude is set too high (e.g. to the maximum value)!
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
1 % 1000 100 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00647 | PolePosId min.mov. cur.rise rate
Data type: UNSIGNED_32
Index: 23928
d
= 5D78
h
From software version V4.0
Percentage adjustment of the rate of current rise for the pole position identification
Adjustment of the pole position identification
Setting range (min. value | unit | max. value) Lenze setting
5 % 1000 100 %
Read access Write access CINH PLC STOP No transfer Scaling factor: 1